nFORCE™ LED Lightbar - 24"
NORMAL OPERATION
Under Normal operation with lightbar turned ON, the breakout box will have the Green LED flash approx every 5 seconds and the Red LED light will
be on steady whenever an input is active and both switches will be in the UP (off) position. Each driver module inside the lightbar has a fused circuit
from the power distribution module. The LED on the driver module will flash whenever there is an active function selected on the breakout box.
NO OPERATION
No Green LED flashing on Breakout box;
NO or INCORRECT INBOARDS or CORNERS LIGHTS (WARNING)
Breakout box LED's operating correctly;
No steady Red LED on breakout box;
NO TAKEDOWNS LIGHTS
Breakout box LED's operating correctly;
No steady Red LED on breakout box;
NO LIGHT OPERATION IN ONLY 1 TUB
Breakout box LED's operating correctly;
Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the automated message).
S U P E R I O R C U S TO M E R R E L AT I O N S H I P S . S M A RT LY D E S I G N E D L I G H T I N G & E L E C T R O N I C S O L U T I O N S .
9.
nForce TROUBLESHOOTING
Check input power and ground to lightbar, check data cable for damage and/or opens.
Check Ignition Input wire and verify a minimum of 10.0 Volts is present on the wire
Defective power distribution assembly – replace.
Check DIP switches on driver modules in lightbar. Verify they are all set correctly
Check 24-pin connector at breakout box (insure it is snapped in correctly),
check appropriate input to breakout box for output lights which should be on.
Verify voltage is present at the wire input to the breakout box for the function being tested
Verify configuration and make sure light modules are configured for takedown function
Check 24-pin connector at breakout box (insure it is snapped in correctly), check appropriate
input to breakout box for output lights which should be on
Remove top cover of tub in which lights are not functioning. Verify DIP switch is set correctly.
Check LED on Driver Module PCB is flashing when power is applied to any input wire on breakout box.
If there is no LED illumination check for voltage across Red and Black power input wires to driver
module. If voltage is present, replace driver module. If voltage is not present, locate the power
distribution PCB (possibly in different tub) and verify fuse is not blown open. If fuse is blown, check for
shorts in cabling replace any damaged cables and replace fuse. If fuse blows again, replace defective
driver module assembly.
Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsigal.com.
IMPORTANT INFORMATION:
nForce Lightbar - 24inch 09.13
Need help?
Do you have a question about the NEXUS TECHNOLOGY nFORCE LED Lightbar 24 and is the answer not in the manual?