Rsp Installation - Cisco NCS 4206 Installing

Table of Contents

Advertisement

RSP Installation

When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let the fan blades completely
stop before you remove the fan tray. Statement 258
Figure 17: Fan Tray Removal
Step 4
Wait at least 5 seconds to allow the fans to stop spinning. Then, pull the fan tray backward toward you and out of the
chassis.
As the fan tray slides out of the chassis, support the bottom of the fan tray with one hand and keep your other
Note
hand on the fan tray handle.
This completes the steps for removing the fan tray from the chassis.
To install the new fan tray, follow the steps in
RSP Installation
Follow these steps on handling an RSP module in the Cisco NCS 4206:
Installing an RSP Module
To install an RSP module in the chassis, perform the following steps:
Step 1
Choose a slot for the module. Ensure that there is enough clearance to accommodate any equipment that will be connected
to the ports on the module. If a blank module filler plate is installed in the slot in which you plan to install the module,
remove the plate by removing its 2 Phillips pan-head screws.
Step 2
Fully open both the ejector levers on the new module, as shown in the figure below.
To prevent ESD damage, handle modules by carrier edges only.
Caution
Installing the Cisco NCS 4206
16
Installing the Fan
Tray.
Installing the Cisco NCS 4206