3-5. Remote 14 Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
F
E
*The remaining sockets are not used.
3-6. Remote 17 Receptacle Information
A
A
B
M
C
L
N
P
T
K
D
R S
R S
J
E
H
G
F
*The remaining sockets are not used.
OM-139 426 Page 10
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
REMOTE
REMOTE
OUTPUT
CONTROL
GND
ST-800 827-A
REMOTE 17
REMOTE
REMOTE
OUTPUT
CONTROL
CONTROL
METER
Voltage Sensing
ST-800 828-A
GND
Socket*
Socket Information
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
C
+10 volts dc output to remote control.
E
0 to +10 volts dc input command signal from re-
mote control.
D
Remote control circuit common.
G
Circuit common for 24 and 115 volts ac circuits.
K
Chassis common.
Socket*
Socket Information
D
Contactor on/off signal; +13 to +24 volts dc con-
tactor on, 0 volts dc contactor off.
A
+10 volts dc output to remote control; allows full
control of A/V output from remote control.
B
0 to +10 volts dc input command signal from re-
mote control.
H
+24 volts dc; fused at 1/2 ampere.
K
0 to +10 volts dc set by panel A/V control; remote
control percent of panel A/V control.
L
–24 volts dc; fused at 1/2 ampere.
E
Current feedback; 0 to +10 volts dc, 1 volt per 100
amperes.
M
Voltage feedback; 0 to +10 volts dc, 1 volt per 10
arc volts.
J
Negative weld output; fused at 1/2 ampere.
N
Positive weld output.
F
Circuit common for sockets A, B, D, E, K, and M.
P
Circuit common for sockets H and L.
S
Chassis common.