5-2. Removing Top Of Case And Measuring Input Capacitor Voltage
1
Tools Needed:
3/8, 7/16 in
5/32 in
OM-139 426 Page 16
Y Significant DC voltage can remain on
capacitors after unit is Off. Always
check capacitors as shown to be sure
they have discharged before working
on unit.
1
Turn Off welding power source and
disconnect input power.
1
To loosen top, remove two outside
handle screws from both handles
and all side bolts.
2
3
Measure the dc voltage across the
positive (+) and negative (–) termi-
nals until voltage drops to near 0
(zero) volts.
Proceed with job inside unit. Rein-
stall top of case when finished.
2
Outside Handle Screws
Input Rectifier SR1
Voltmeter
3