Placing Jumper Links - Miller XMT 400 CC/CV Owner's Manual

Table of Contents

Advertisement

3-7. 115 Volt AC Receptacle
3-8. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output (I
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Reference: 1993 National Electrical Code (NEC).

3-9. Placing Jumper Links

Tools Needed:
115 VOLTS AC
)
eff
380 Volts
1
1
415 Volts
2
1
115 Volt AC Receptacle
(Twistlock Shown)
The receptacle on the rear of this
unit supplies up to 5 amperes of 115
volt ac power. The receptacle is
commonly used to power a cooling
system. The receptacle may be
twistlock or standard.
Power output is shared between
this receptacle and the Remote 14
receptacle (see Section 3-5).
ST-146 127-C
380
415
26
24
40
40
Y Significant DC voltage can
remain on capacitors after
unit is Off. Always check ca-
pacitors according to Sec-
tion 5-2 before working on
unit.
Check input voltage available at
site.
1
Jumper Link Label
2
Jumper Links
Move jumper links to match input
voltage.
Reinstall top of case.
ssb5.1* 2/92 – Ref. ST-153 971-D / Ref. S-145 063
OM-139 426 Page 11
S-0092J

Advertisement