InjectorCyl#2
Injector fault.
InjectorCyl#3
Injector fault.
InjectorCyl#4
Injector fault.
InjectorCyl#5
Injector fault.
InjectorCyl#6
Injector fault.
OverrideFail
SDM override cable failure or resistor missing.
PickupCam
Camshaft speed sensor.
Cable failure or deviation in the measured value against crankshaft.
•
Engine runs unevenly.
•
Engine is difficult to start or does not start.
PickupCrank
Crankshaft speed sensor
Cable failure or deviation in the measured value against camshaft.
•
Engine runs unevenly.
•
Engine is difficult to start or does not start.
PrimarySupply
SDM Low power supply primary battery.
•
Poor batteries or charging. Refer to Battery, Charging.
•
Check F1 fuse in SDM box.
SecSupply
SDM Low power supply secondary battery.
•
Poor batteries or charging. Refer to Battery, Charging.
•
Check F2 fuse in SDM box.
47710406 10-2018 © AB VOLVO PENTA
Fault Code Register
53