Volvo Penta D13 Operator's Manual page 104

Hide thumbs Also See for D13:
Table of Contents

Advertisement

Technical Data
Water Quality
ASTM D4985:
Total solid particles
Total hardness
Chloride
Sulfate
pH value
Silica (acc. ASTM D859)
Iron (acc. ASTM D1068)
Manganese (acc. ASTM D858)
Conductivity (acc. ASTM D1125)
Organic content, COD
Mn
Electrical System
System voltage
AC generator:
Voltage/max. amperage
Output, approx.
Alternative generator equipment (accessory):
Voltage/max. amperage
Output, approx.
Alternative generator equipment (accessory):
Voltage/max. amperage
Output, approx.
Battery capacity
Battery electrolyte density at +25°C (77°F)
Fully charged battery
Battery recharged at
1) Applies to batteries with tropical acid.
2) Applies to batteries with tropical acid.
102
(acc. ISO8467)
24V
28V/110A
2640W
28V/110A
2640W
14V/115A
1610W
2 connected in series 12V, max. 220 Ah
1.28 g/cm
(1.24 g/cm
1.24 g/cm
(1.20 g/cm
<340 ppm
<9,5° dH
<40 ppm
<100 ppm
5.5–9
<20 mg SiO
/l
2
<0.10 ppm
<0.05 ppm
<500 µS/cm
<15 mg KMnO
/l
4
3
3
= 0.0462 lb/in
3
3
(1)
= 0.0448 lb/in
)
3
3
= 0.0448 lb/in
3
3
(2)
= 0.0434 lb/in
)
47710406 10-2018 © AB VOLVO PENTA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents