Ventilation System; Brewer - BRAVILOR BONAMAT FRESHONE (G) Operating Principle

Table of Contents

Advertisement

1.6

Ventilation system

The ventilation system (Fig. 17/18) ensures that the hot steam that is produced during dosing can escape.
This prevents the hot steam from settling and condensation from forming in the mixing chamber. This
substantially decreases the amount of filth that can settle in the mixing chamber.
Fig. 17 Ventilation system – FreshOne, FreshMore,
FreshGround
1.7

Brewer

The brewer works according to the vacuum principle, whereby ground coffee and hot water are drawn
through a micro fine filter and filter paper into a cylinder by a housing.
Pressing a selection button that uses FreshBrew coffee starts the following process:
D Ground coffee and hot water are dosed in the top of the brewer through the water selector. The brewer
housing is in its idle position in the cylinder just above the opening of the outlet (Fig.19A).
D The housing rises pressing air upward and out of the cylinder. This air movement ensures that the coffee
is thoroughly mixed with the hot water.
D To prevent the mixture of coffee and hot water from flowing over the mixing chamber (when the coffee
dose is high) a brew stop [Stop 0] between 0 and 10 seconds can be programmed to take place halfway
through this process (Fig.19B).
D The housing stops for a few seconds at the very top to stimulate the extraction. The stop can be
programmed from 0 to 10 seconds = [Stop 1] (Fig.19C).
D The housing then lowers so the coffee extract can be sucked through the filter paper.
D Before the coffee extract leaves the brewer, the housing stops again [Stop 2] for anywhere between 0 to
10 seconds to extract as much fresh coffee as possible from the coffee residue (Fig.19D).
D The housing then lowers further, releasing the opening of the outlet so the coffee extract can flow through
the coffee outlet into a cup, mug or jug.
D When the brewer is dosing empty, an additional (3
can flow out slower (Fig.19E).
D After dosing, the housing moves downward and automatically transports the filter paper and the coffee
residue to the waste bin (Fig.19F).
D The housing then moves upward into its idle position just above the opening of the outlet.
The brewer is ready for the next cycle (Fig.19G).
Fig. 19 Brewer
Fig. 18 Ventilation system – FreshMore XL,
FreshGround XL
) non−settable stop takes place so the dosed coffee
rd
7