1.
GENERAL
1.1
The machine
1.1.1
General description
The machines from the RLX series are designed
for making coffee, for supplying hot water and for
heating drinks using steam.
One machine is an assembly comprising one or
more modules.
In this document, the general information for all
modules is discussed.
Please also read the user instructions for the
specific modules.
1.1.2
The modules
The figures in the model description indicate the
modules comprising your particular machine.
In table 1 , the various standard modules are
shown.
Module
Type
1
coffee
2
wide body
3
hot water
4
hot water/steam
5
coffee
6
coffee
7
hot water
8
hot water/steam
Table 1 The various modules
Example:
The RLX 231 comprises:
D a wide body module (2) on the left,
D a low model hot–water module (3) in the
middle, and
D a glass–jug coffee module (1) on the right.
TIP
– See the fold–out for the standard models.
ECopyright Bravilor Bonamat B.V.
1.1.3
Depending on the configuration, your machine
may be equipped with a preferred circuit. An
electronic circuit within the machine will make
sure that no two high–powered modules can be
switched on at the same time. If your machine is
equipped with a preferred circuit, the coffee
module will be in the preferred position. This
means that the other modules will be switched off
or partly switched off by the control system, as
soon as the coffee module is switched on. Ask
your Bravilor Bonamat dealer, your service
technician, or one of the service agencies about
the various options.
1.2
1.2.1
Remark
with glass jug
D See the fold–out.
with hot plate
low model
1.2.2
low model
D See the identification plate for the correct
with container
with airpot
high model
1.2.3
high model
1.2.4
Cleaning material : CLEANER
Descaler
D See §1.7.1 for ordering the cleaning and
Preferred circuit
Technical data
Weights and
measurements
Electrical system
values.
Water system
– Water hardness
:
– Min. water pressure
(supply)
:
– Max. water pressure
(supply)
:
– Flow–rate
:
– Conductivity
:
Recommended cleaning
and descaling agents
: RENEGITE
de–scaling materials.
min. 5 _DH
50 kPa (0,5 bar)
1000 kPa (10 bar)
5,5 l/min
100 µ Siemens/cm
1
version
1.0