Quick Start Guide PA22 Version: 1.0 Due to the regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Device Overview Front Side 2.4 Inch TFT LCD Keypad & RF Card Area Reset Button LED Indicator Near-infrared Palm Speaker Recognition Sensor Back Bottom USB Slot Tamper switch Back Plate Terminal Block Mounting Hole Wiring Hole...
Device Dimensions 3.18" 0.76" (80.7mm) (19.4mm) 2.21" (56.1mm) 6.29" 4.97" (159.8mm) (126.1mm) 1.61" (41.0mm) Device Installation Install on the Wall Attach the mounting template sticker to the wall, and drill the holes according to the mounting paper. Fix the back plate on the wall with using wall mounting screws. Attach the device to the back plate from top to bottom.
Power Connection Without UPS +12V DC 12V DC Adaptor With UPS (Optional) +12V DC Recommended Power Supply: 12V±10%, at least 3000MA. Use an AC adapter with a higher current ratings to share the power with other devices.
Ethernet Connection LAN Connection Connect the device and the software over an Ethernet cable. An example is shown below: RJ45-1 RJ45-2 RJ45-3 RJ45-6 Network Cable Adaptor Default IP address: 192.168.1.201 IP address: 192.168.1.130 Subnet mask: 255.255.255.0 Subnet mask: 255.255.255.0 Click [Comm.] >...
Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (Normally Opened when powered) is connected with “NO” and “COM” terminals, and the NC Lock (Normally Closed when powered) is connected with “NC” and “COM” terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below: Device Not Sharing Power with the Lock BELL-...
Page 9
RS485 Connection RS485 Fingerprint Reader Connection 12V DC Adaptor 485B 485A RS485 Fingerprint Reader DIP Settings There are six DIP switches which are located on the back of RS485 ngerprint reader: switches 1 to 4 are for RS485 address, switch 5 is reserved, switch 6 is for noise reduction on long RS485 cable.
Device Operation User Registration [M/OK] When there is no super administrator set in the device, click to enter the menu. Add a new user and set their User Rule to Super Admin, then the system will ask for the administrator’s approval before allowing them to access the menu. For security reasons, we highly recommend that you register a super administrator promptly.
Page 12
Ethernet and Cloud Server Settings Click [M/OK] > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Click [M/OK] > [COMM.] > [Cloud Server Setting] to set the server address and server port, i.e., the IP address and port number of the server after the software is installed.
Page 13
Access Control Setting Click [M/OK] > [Access Control] to enter the access control management interface and set relevant parameters for the access control.
Page 14
Attendance Record Click [M/OK] > [Attendance Search] > [Attendance Record] to enter the records query interface, input the user ID and select the time range. The corresponding attendance logs will then be displayed.