Junction box with electronic thermostat module
Table of Contents

Advertisement

Operation and Installation Manual PBTC-300
CAUTION
Risk of malfunction of the heating system. Before you continue, make sure that the bus wires are intact and not nicked
or damaged.
 Remove any remaining heating element that sticks to the bus wires
 Twist the bus wires
 Remove the remaining heating element
 Take care not to damage the bus wires
 Cut in a triangle between the bus wires. (triangle 5 mm)
 Take care not to damage the bus wires
21-54C3-7D0002/-
Notice: Technical data subject to change without notice.
01/2022-EHT-441169
No claims for damage arising from alternations, errors or misprints shall be allowed.
 Make sure that all bus wires are intact and not nicked or
damaged.