Digigram ALP442e User Manual page 23

Professional multi-channel sound card
Table of Contents

Advertisement

User Manual for ALP442e & ALP442e-MIC
ALP882e & ALP882e-MIC
,
If the internal clock is selected ("Internal"), select the sampling
Rate value from the "Internal Sampling Rate" selection list.
Possible values are: (in kHz)11.025, 16, 22.05, 24, 32, 44.1, 48, 64,
88.2, 96, 128, 176.4, 192, and Application.
Selecting "Application" means that the sampling frequency is set
by the application.
Setting the card to one of the frequency values means that a
software application that uses the card must be configured at the
same frequency value.
If an external clock is selected, the card is synchronised to it as
long as it is present.
If the external clock signal is lost, the ALP card falls back to its
internal clock, which is automatically set at the same frequency as
the external clock.
The clock source used at a given moment is displayed in the "Sync
Source" field, and its frequency value is given by the "Sampling
Rate" field.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alp442e-micAlp882eAlp882e-mic

Table of Contents