Advertisement

Quick Links

FilterWall
IM2 Series System User Guide
M A I N S W A T E R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FilterWall IM2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Puretec FilterWall IM2 Series

  • Page 1 FilterWall IM2 Series System User Guide M A I N S W A T E R...
  • Page 2: Table Of Contents

    Builder Plans ................................8 Installation - Enclosure ..........................26 Installation - Filter Assembly ........................26 Installation - Filter Cartridges .........................27 Cartridge Replacement ..........................28 Warranty ................................30 AS3497 Licence No. WM 74617 Pro-Switch Pty Ltd Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 3: Important Information

    INSTALLATION MUST BE COMPLETED BY A LICENCED PLUMBER. FAULTY OPERATION DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED WARRANTY COVERAGE. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 4: Preparing Your System

    Preparing Your System Preparing Your System Thank you for purchasing a Puretec quality product. Puretec systems are designed to run economically for many years, dependent on the initial installation and periodical maintenance. Please read all instructions carefully as failures caused by incorrect installation or operation are not covered by warranty.
  • Page 5: Installation Requirements

    Select a suitable outlet connector 20 mm BSPF (not supplied) Installation Record For future reference, fill in the following data: Product Information Model Number: Serial / Batch Number: Purchased from: Date of Installation: Installer / Plumber Details: Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 6 Parts Diagram Fig. 1 - Parts Diagram, Enclosure Filter Assembly Mounting Studs Outlet Entry Protrusion Lockable Latch Inlet Entry Protrusion Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 7 & Non-Return Brass Adaptor 3/4" F x 3/4" M Water Inlet Housing Bowl Housing Bowl with Sediment with Carbon Cartridge Block Cartridge Bypass Shut Off Water Valve Outlet (closed during normal use) Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 8: Builder Plans

    Housing Brick Tie Brick Tie Housing Brick Brick Tie Brick Tie BRICK TIE MOUNTING TO HOUSING (TOP VIEW) Brick DETAIL A BRICK TIE MOUNTING TO HOUSING (TOP VIEW) DETAIL A Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 9 PEX or Copper Tubing (not supplied) DETAIL B Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 10 TOP VIEW Wall Opening WALL CUTOUT ELEVATION Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. 10 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 11 Sealant around the FilterWall. Timber Fasteners SECTION A-A (not supplied) 90mm Stud 70mm Brick 6mm Rendered Wall SECTION B-B Packing Shims (not supplied) ELEVATION PEX or Copper Tubing (not supplied) DETAIL A Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 12 ELEVATION Mortar Brick Rivet When mounted to housing the brick ties have a 4˚angle. Housing Brick Tie Brick Tie Brick BRICK TIE MOUNTING TO HOUSING (TOP VIEW) DETAIL A 12 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 13 (not supplied) DETAIL B Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. MOUNTING TO HOUSING (TOP VIEW) Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 14 WALL CUTOUT ELEVATION WALL CUTOUT ELEVATION ELEV Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. 14 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 15 Sealant around the FilterWall. Timber Fasteners SECTION A-A (not supplied) 90mm Stud 110mm Brick 6mm Rendered Wall SECTION B-B Packing Shims (not supplied) ELEVATION PEX or Copper Tubing (not supplied) DETAIL A Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 16 Rivet Brick When mounted to the housing the brick ties have a 4° angle. Housing Brick tie Brick Tie Brick BRICK TIE MOUNTING TO HOUSING (TOP VIEW) DETAIL A 16 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 17 DETAIL B S.M. OUNTING TO HOUSING (TOP VIEW) Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 18 WALL CUTOUT ELEVATION WALL CUTOUT ELEVATION Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. 18 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 19 Min 4 x M6 x 30mm Sealant around the FilterWall. Timber Fasteners SECTION A-A (not supplied) 90mm Stud 70mm Brick SECTION B-B Packing Shims (not supplied) ELEVATION PEX or Copper Tubing (not supplied) DETAIL A Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 20 Brick Rivet When mounted to the housing the brick ties have a 4° angle. Housing Brick Tie Brick Tie Brick DETAIL A BRICK TIE MOUNTING TO HOUSING (TOP VIEW) 20 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 21 DETAIL B Note: All dimensions are shown in millimetres. ICK TIE MOUNTING TO HOUSING (TOP VIEW) Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 22 Wall Opening WALL CUTOUT ELEVATION ELEVATI Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. 22 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 23 Min 4 x M6 x 30mm Sealant around the FilterWall. Timber Fasteners SECTION A-A (not supplied) 90mm Stud 110mm Brick SECTION B-B Packing Shims ELEVATION (not supplied) PEX or Copper Tubing (not supplied) DETAIL A Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 24 Note: All dimensions are shown in millimetres. Disclaimer: Example installation shown, individual requirements may vary. Ensure Australian Building Standards are met during installation. Hebel® is a registered trademark of Xella Group. 24 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 25 Sealant around the FilterWall. Timber Fasteners SECTION A-A (not supplied) 90mm Stud 75mm Hebel® 6mm Rendered SECTION B-B Packing Shims (not supplied) ELEVATION PEX or Copper Tubing (not supplied) DETAIL A Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 26: Installation - Enclosure

    Feed the mains water outlet pipe (Copper or PEX) through the exit protrusion on the RIGHT side of the enclosure. Temporarily bridge the inlet and outlet connections (fittings not supplied) if Filter Assembly is to be installed at a later date. 26 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 27: Installation - Filter Cartridges

    If the water supply was on, open up a downstream tap to relieve pressure to the system. Ensure the bypass shut off valve is in the CLOSE position and turn the outlet shut off valve into the CLOSE position. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 28: Cartridge Replacement

    (filters are blocked with sediment and other containments) or bad taste and odour return. You can obtain replacement cartridges from your local Puretec dealer. To maintain performance standards and system warranty, use only genuine Puretec replacements.
  • Page 29 Check the O-rings for damage and lubrication. If necessary, apply a light coating of food grade silicone lubricant (or similar). Note: Puretec recommends replacing the O-rings every 3-5 years to ensure the seal remains watertight and prevents any leaks. Replacement O-ring ordering code: MPOR-G Remove all packaging from the cartridges, including any wraps.
  • Page 30: Warranty

    Puretec’s discretion, including chargeable inspection and labour costs incurred. Warranty/Australia This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road, Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au.
  • Page 31 Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 32 MAR2023...

Table of Contents