Advertisement

Quick Links

FilterWall
IMF2 Series System User Guide
M A I N S W A T E R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FilterWall IMF2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Puretec FilterWall IMF2 Series

  • Page 1 FilterWall ™ IMF2 Series System User Guide M A I N S W A T E R...
  • Page 2: Table Of Contents

    Fasica Assembly Instructions ........................11 Mounting The Fascia Frame To The FilterWall™ Enclosure .............12 Installation .................................13 Cartridge Replacement ..........................14 Bypass Shut Off Valve ..........................15 Warranty ................................16 AS3497 Licence No. WM 74617 Pro-Switch Pty Ltd Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 3: Important Information

    INSTALLATION MUST BE COMPLETED BY A LICENCED PLUMBER. FAULTY OPERATION DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED WARRANTY COVERAGE. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 4: Preparing Your System

    Preparing Your System Preparing Your System Thank you for purchasing a Puretec quality product. Puretec systems are designed to run economically for many years, dependent on the initial installation and periodical maintenance. Please read all instructions carefully as failures caused by incorrect installation or operation are not covered by warranty.
  • Page 5: Installation Requirements

    Select a suitable outlet connector 20 mm BSPM (not supplied) Installation Record For future reference, fill in the following data: Product Information Model Number: Purchased from: Date of Installation: Installer / Plumber Details: Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 6 Parts Diagram Fig. 1 - Parts Diagram, Enclosure Filter Assembly Mounting Studs Outlet Entry Protrusion Lockable Latch Inlet Entry Protrusion Fascia Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 7 & Non-Return Brass Adaptor 3/4" F x 3/4" M Water Inlet Housing Bowl Housing Bowl with Sediment with Carbon Cartridge Block Cartridge Bypass Shut Off Water Valve Outlet (closed during normal use) Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 8 Builder Plans Fig. 3 - Internal Wall Installation 610 mm Secondary Jam Stud Internal Stud Spacing 603 mm Wall Cutout Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 9 Builder Plans Fig. 4 - Internal Wall Installation econdary Jam Stud Section B-B Min 4 x M Timber Fa 2 x 4.2 x 20 mm Tek Screw 100 mm minimum depth shown. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 10 2 x 4.2 x 20 mm Tek Screw Noggin x 2 Min 4 x M6 x 30 mm Timber Fasteners 2 x 4.2 x 20 mm Tek Screw Plasterboard Packer 100.00 Minimum Depth Required 10 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 11: Fasica Assembly Instructions

    #2 Phillips Head Drill Bit • 3-4 mm metal drill (optional) • Rubber Mallet (optional) Horizontal Rail Angled Bracket Vertical Post Tek Screw (used to attach the fascia frame to the enclosure) RHS Inserts Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 12: Mounting The Fascia Frame To The Filterwall™ Enclosure

    Tip: Pre-drill pilot holes using a small drill bit (3-4 mm) to reduce the likelihood of damage to the enclosure. Now that the fascia frame has been installed onto your FilterWall™ enclosure, it is ready to be mounted. 12 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 13: Installation

    13. Check that all pre-installed connections on the system are secure and have not loosened in transit. 14. Feed the mains water inlet pipe (Copper or PEX, not supplied) through the entry protrusion on the LEFT side of the enclosure. Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 14: Cartridge Replacement

    (filters are blocked with sediment and other containments) or bad taste and odour return. You can obtain replacement cartridges from your local Puretec dealer. To maintain performance standards and system warranty, use only genuine Puretec replacements.
  • Page 15: Bypass Shut Off Valve

    11. If leaks occur, repeat the steps to check cartridge alignment and bowl O-rings. If leaks persist, turn the inlet and outlet shut off valves to the CLOSE position and the bypass isolation to the OPEN position and call Puretec on 1300 140 140 (AU) or 0800 130 140 (NZ).
  • Page 16: Warranty

    Puretec’s discretion, including chargeable inspection and labour costs incurred. Warranty/Australia This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road, Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au.
  • Page 17 Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 18 18 Installation & Operation Manual Copyright © Puretec Pty Ltd 2023...
  • Page 19 Copyright © Puretec Pty Ltd 2023 FilterWall User Guide...
  • Page 20 9 341 362 02 863 1 DEC2023...