2) For A97*/960GOT
• Wind cable shield material around the cable, and pull out the
grounding braided wire of the cable shield material with the length
shown below.
• Pass the grounding braided wire on the programmable logic
controller side through the core.
GOT side
130
(5.12)
Within 150
(5.90)
(b) RS-232C
• Use a twisted pair style for each signal wire (except SG, FG) with SG.
RD
SD
DTR
DSR
SG
• Strip the outer insulation layer at both ends of the cable by the length
shown below to expose the braided shield for grounding. (For
grounding with cable clamps. (refer to Section 5.6.3.))
GOT side
130
(5.12)
Within 230
(9.06)
Ferrite Core
(ZCAT3035-1330)
Cable shield material
Grounding braided
wire(50mm(1.97inch))
Ferrite Core
(ZCAT3035-1330)
40
(1.57)
Other
PLC side
Near the connection
destination
Other PLC and Microcomputer side
Near the connection
40
destination
Near the connection
(1.57)
destination
36
Near the connection
destination
Unit : mm (inch)
SD
RD
DSR
DTR
SG
Unit : mm (inch)