Appendix B - Sia Format - DSC PC5508 Manual

Table of Contents

Advertisement

SIA Format
Level 2 (Hardcoded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communica-
tion Standard - January 1996. This format will send the Account Code along with its data transmission. At the
receiver, the transmission would look similar to this example:
N Ri01
BA 01
N = New Event
Ri01 = Partition / Area Identifier
BA = Burglary Alarm
01 = Zone 1
PC5010 Reporting Codes
Delay Zone Alarm / Restore ................................. BA-XX / BH-XX *
Instant Zone Alarm / Restore ................................ BA-XX / BH-XX *
Interior Zone Alarm / Restore ............................... BA-XX / BH-XX *
Delay S.A. Zone Alarm / Restore ......................... BA-XX / BH-XX *
Interior S.A. Zone Alarm / Restore ....................... BA-XX / BH-XX *
24 Hr Burg Zone Alarm / Restore ......................... BA-XX / BH-XX *
Standard Fire Zone Alarm / Restore ..................... FA-XX / FH-XX *
Delayed Fire Zone Alarm / Restore ....................... FA-XX / FH-XX *
2-Wire Smoke Alarm / Restore ............................... FA-99 / FH-99
24 Hr Supervisory Buzzer Zone Alarm / Restore . UA-XX/ UH-XX *
24 Hr Supervisory Zone Alarm / Restore ............. UA-XX / UH-XX *
24 Hr Medical Zone Alarm / Restore .................. MA-XX / MH-XX *
24 Hr Panic Zone Alarm / Restore ........................ PA-XX / PH-XX *
24 Hr Holdup Zone Alarm / Restore ..................... HA-XX / HH-XX *
24 Hr Gas Zone Alarm / Restore ......................... GA-XX / GH-XX *
24 Hr Heat Zone Alarm / Restore ......................... KA-XX / KH-XX *
24 Hr Emergency Zone Alarm / Restore ............. QA-XX / QH-XX *
24 Hr Sprinkler Zone Alarm / Restore ................... SA-XX / SH-XX *
24 Hr Water Zone Alarm / Restore ...................... WA-XX / WH-XX *
24 Hr Freeze Zone Alarm / Restore ...................... ZA-XX / ZH-XX *
24 Hr Latching Tamper Alarm / Restore .............. BA-XX / BH-XX *
Duress Alarm ...................................................................... HA-00
Opening After Alarm .......................................................... OR-00
Recent Closing .................................................................... CR-00
Zone Expander Supervisory Alarm / Restore ......... UA-00/UH-00
Keypad Fire Alarm / Restore .................................. FA-00 / FH-00
Keypad Auxiliary Alarm / Restore ........................ MA-00 / MH-00
Keypad Panic Alarm / Restore .............................. PA-00 / PH-00
Audible / Silent 24 Hr ............................................. UA-99 / UH-99
Zone Tamper (1-32) ............................................................ TA-XX *
* Zone Number is Identified
User Number is Identified
Each Zone Number is Identified (using UB-XX)
Appendix B
S
I
A
V
F
O
SIA Identifiers &
PC5010 Reporting Codes
Auto-Reporting Code
Zone Tamper Restorals (1-32) ........................................... TR-XX *
General System Tamper / Restore ......................... TA-00 / TR-00
Keypad Lockout .................................................................. JA-00
Closing By Access Codes 1-32, 33, 34, 40-42 ................. CL-XX
Partial Closing .................................................................... CG-XX
Special Closing (DLS, Keys, Maint, Quick) ....................... CL-00
Opening By Access Codes 1-32, 33, 34, 40-42 .............. OP-XX
Auto-Arm Cancellation ........................................................ CE-00
Special Opening (DLS, Keys, Maint) ................................. OP-00
Battery Trouble Alarm / Restore .............................. YT-00 / YR-00
AC Failure Trouble Alarm / Restore ........................ AT-00 / AR-00
Bell Circuit Trouble Alarm / Restore ........................ UT-99 / UJ-99
Fire Trouble Alarm / Restore ..................................... FT-00 / FJ-00
Auxiliary Power Supply Trouble Alarm / Restore ... YP-00 / YQ-00
TLM Trouble Code (via LINKS) ........................................... LT-00
General System Trouble / Restore .......................... YX-00 / YZ-00
General System Supervisory / Restore ................... ET-00 / ER-00
TLM Restoral ....................................................................... LR-00
FTC Restoral ....................................................................... YK-00
Event Buffer 75% Full Since Last Upload .......................... JL-00
DLS Lead In ........................................................................ RB-00
DLS Lead Out (Successful) ................................................ RS-00
Periodic Test Transmission ................................................ RP-00
System Test ......................................................................... RX-00
LINKS1000 Test Transmission ........................................... TX-00
General Transmitter Low Battery / Restore ............ XT-00 / XR-00
General Zone Trouble / Restore .............................. UT-00 / UJ-00
Activity / Closing Delinquency ........................................... CD-00
Cross Zone Police ............................................................... BV-00
42
R
M
A
T
SIA Identifiers &
Auto-Reporting Code