P
R
O
G
A Partial Closing Reporting Code will be transmitted if a Partition is armed with zones manually
bypassed. The code will also be transmitted if a Partition Auto Arms with zone(s) in violation.
A Special Closing Reporting Code will be transmitted if the Partition(s) is armed using any of the
following methods:
• Quick Arm
• Arming via the DLS Software
• Auto Arm
• Arming via keyswitch
A Closing by Duress Code Reporting Code will be transmitted in addition to the Duress reporting code if
a Partition(s) is armed using a Duress Code.
A Recent Closing Reporting Code will be transmitted if an alarm occurs within 2 minutes of the exit delay
expiring.
5.7.4

Openings

The panel will transmit an Opening Reporting Code to indicate a Partition(s) has been disarmed. A
different reporting code can be transmitted for each User Code, Partition Master Code and System Master
Code to identify who disarmed the Partition(s).
A Special Opening Reporting Code will be transmitted if the Partition(s) is disarmed using any of the
following methods:
• Disarming using the Maintenance Code
An Opening After Alarm Reporting Code will be transmitted in addition to the opening when the
Partition(s) is disarmed after an alarm has occurred.
An Opening by Duress Reporting Code will be transmitted in addition to the Duress reporting code if a
Partition(s) is disarmed using a Duress Code.
5.7.5

Tampers

If the panel is programmed for Double EOL zones (See Section 2.9 "Zone Wiring") the panel will report a
Zone Tamper Alarm Reporting Code if an open condition is present on a zone. A different reporting code
can be programmed for each zone for identification. The Zone Tamper Restoral Reporting Code will be
transmitted immediately when the tamper condition is restored.
A General System Tamper Reporting Code will be transmitted when the tamper zone on any module is
violated. The General System Tamper Restoral Reporting Code will be transmitted when the tamper
zone on the module is restored.
5.7.6

Priority/Emergency

The panel will transmit a Keypad Fire Alarm Reporting Code AND the Keypad Fire Restoral Reporting
Code when the Fire Keys on any keypad is pressed for two seconds.
The panel will transmit a Keypad Auxiliary Alarm Reporting Code AND the Keypad Auxiliary Restoral
Reporting Code when the Auxiliary Keys on any keypad is pressed for two seconds.
The panel will transmit a Keypad Panic Alarm Reporting Code AND the Keypad Panic Restoral
Reporting Code when the Panic Keys on any keypad is pressed for two seconds.
The panel will transmit a Duress Reporting Code any time either Duress Code is entered at any keypad. If
the panel is armed using the Duress Code the panel will also transmit a Closing by Duress Reporting
Code or if the panel is disarmed it will also transmit an Opening by Duress Reporting Code.
If PGM2 is being used for two wire smoke detectors (See Section 5.10 "PGM Outputs") the panel will send
a PGM2 Alarm Reporting Code if a smoke detector goes into alarm. The panel will transmit the PGM2
Alarm Reporting Code when the zone is restored.
If you use the SIA automatic reporting format, the panel will send "Two Wire Smoke Alarm/Restoral"
reporting code.
5.7.7

Maintenance

The panel will transmit a Battery Trouble Alarm Reporting Code when the backup battery drops below
11.5 V
. The Battery Trouble Restoral Reporting Code will not be transmitted until the battery has been
DC
charged over 12.5 V
To prevent the panel from transmitting an AC Failure Trouble Alarm Reporting Code during short power
outages the panel will not send the signal unless AC power is lost for the amount of minutes programmed
for the AC Failure Communication Delay. The AC Failure Trouble Restoral Reporting Code will be
transmitted once AC power has been restored for the amount of time programmed for AC Failure.
Communication delays. NOTE: If AC Failure Communications Delay is programmed as 000, the AC
Failure Trouble reporting code will be sent immediately.
A Bell Circuit Trouble Alarm Reporting Code will be transmitted immediately if an open condition is
measured on the Bell Output of the main panel. The Bell Circuit Trouble Restoral Reporting Code will be
transmitted as soon as the problem is corrected.
A Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on
any Fire type zone (See Section 5.1 "Zone Definitions"). The Fire Trouble Restoral Reporting Code will be
transmitted as soon as the problem is corrected.
R
A
M
D
.
DC
E
S
C
R
I
• 'Away' Function Key arming
• Arming with the Maintenance Code
• Disarming via the DLS Software
28
P
T
I
O
N
• 'Stay' Function Key arming
• Disarming via keyswitch