1.1.1 Intelli-Protect
Configurable No-Fly Zone systems utilize laser positioning sensors installed on bridge/trolley motions that
interface with a No-Fly Zone controller. This system incorporates a simplified menu-driven operator
interface accessed over a wireless connection via the use of a Personal Electronic Device (PED) such as a
laptop, smartphone, or tablet.
Figure 1-1: Configurable NFZ Example Configurations (Overhead Traveling Bridge Crane)
Enable and configure up to 31 No-Fly Zones
Quickly define NFZ boundaries using two diagonal corner positions while positioning hoist or enter
location manually
Determine position using lasers for 50,150, and 300 meter spans
Define bridge and trolley slow, stop, and protected boundaries using laser positioning
Using a PED (smartphone, tablet), open a Zone Overview screen:
See NFZ boundaries on runway floor plan
See updated position of the crane as it moves
See active zone states (red - within restricted zone, yellow - within stop zone, blinking yellow -
within slowdown zone, green - outside of zone)
Light stack with horn for visual and audible notifications
Hoist upper travel limit switch provides the option to fly over selected zones when enabled
Machine lowered signal provides the option to disable movement when a machine is blocking a path
(Zone 1 only)
One external key switch to disable protection zones
One external key switch to disable Wi-Fi