4.4 Zone Setup

To configure the location of a No-Fly Zone, first disable the zone by clearing the 'Enable' checkbox. On
initial setup, all zones are disabled by default. Each zone is numbered from 1 to 31. Use the Previous and
Next buttons at the top of the menu to scroll between all 31 zone configurations.
Each zone displays a user-customizable ID descriptor or name for added clarity.
Position the hoist at one corner of the desired zone and press the Teach Initial Corner button to store the
initial corner position of the zone.
Position the hoist at the diagonal corner of the desired zone and press the Teach Diagonal Corner button
to store the corner position and finalize the zone.
If needed the data can be entered manually by pressing on the measurement. The value entered can be
beyond the configured travel limits.
1. Zone Configuration
a. Press the previous or next buttons until
the desired zone number appears
b. Press the Enable button to remove the
check box if enabled
c. Move hoist to one corner
d. Press Teach Initial Corner button
e. Move hoist to opposite diagonal corner
f.
Press Teach Diagonal Corner button
g. Move the hoist away
h. Press the Enable button to enable zone
protection
i.
Press the ID field to enter a name
Figure 4-6: Configuring and Enabling a Zone
Intelli-Protect User Manual