1.1.2 Intelli-Protect
Fixed location No-Fly Zones systems utilize limit switches installed on bridge/trolley motions that interface
with a No-Fly Zone controller.
Figure 1-2: Four-Sided Fixed Location NFZ Example (Overhead Traveling Bridge Crane)
Detect slowdown, stop, and protected boundaries using windmill limit switches for bridge and trolley
motions.
Using a Personal Electronic Device (PED) (smartphone, tablet), connect to controller and view inputs,
outputs, and status information.
Light stack with horn for visual and audible notifications
Hoist upper travel limit switch provides the option to fly over selected zones when enabled
Machine lowered signal provides the option to disable movement when a machine is blocking a path
One external key switch to disable protection zones
One external key switch to disable Wi-Fi
4-pole normally closed limit switches are used to detect the slowdown (warning) boundary, stop
boundary crossing, and breach of a protected zone boundary
Fixed location No-Fly Zones require trip arms to trigger the limit switches (Not provided with
Intelli-Protect)
Fixed Location No-Fly Zones
®