7.2 Alarms and Corrective Actions During Operation

Example alarms on configurable systems:
Alarm
Bridge Sensor Fault
Trolley Sensor Fault
Bridge Sensor Communication
Fault
Trolley Sensor Communication
Fault
The Alarms screen button only displays all currently active alarms.
Figure 7-1: Alarm Examples
Description
Sensor is not receiving a
strong enough signal.
Sensor is not receiving
expected information.
Sensor is not receiving
expected information.
Corrective Action
1.
Clean the Bridge or Trolley laser lens
with a lens tissue or cleaning cloth.
Using a circular motion, gently remove
oil, fingerprints, and grime from the lens
surface.
2.
Clean the reflector surface to remove
oil, fingerprints, and grime.
1.
Check the ethernet cable connection to
the Bridge laser.
2.
Check the external components circuit
breaker.
1.
Check the ethernet cable connection to
the Trolley laser.
2.
Check the external components circuit
breaker.