Hillco JS7020 Operator's Manual page 40

Table of Contents

Advertisement

The Active Alarms that will appear are:
Clinometer Fault
Carriage Sensor Fault
Joystick Fault
If any of the sensors output fall outside of the
expected range an alarm will trigger on the screen
listing the fault and the current output of the sensor
in question. While the alarm screen can be cleared
the automatic function of the leveling system may
be disabled until the fault is corrected. Once an
alarm screen has been cleared the fault condition
is denoted by an alert icon in the top left of the
screen. If the icon is displayed then the active
alarms screen in the system menu will show which
sensors are in a fault condition.
Carriage sensor Fault
Clinometer Fault
D-171206CMA01C
Hillco Technologies, Inc.
37
Active Alarms
Clinometer Fault
Carriage Sensor Fault
Joystick Fault
A
Home
Carriage Sensor Fault
Output out of range
Output 4522
Slope: 1
Automatic leveling disabled
Press esc key to clear
Menu
Menu
Home
Clinometer Fault
Output out of range
Fore/Aft output
Slope: 1
Left/Right output 4
Automatic Leveling Disabled
Press esc key to clear
Menu
Menu
MAN
ROAD
MAN
2
ROAD
Sept, 2022

Advertisement

Table of Contents
loading

Related Products for Hillco JS7020

This manual is also suitable for:

Js9020

Table of Contents