Hillco JS7020 Operator's Manual page 31

Table of Contents

Advertisement

After you select Calibration the message to the right
appears.
Press Enter (A)
Joystick Calibration
Highlight Joystick and press Enter (B).
Notice
When in the Calibration Menu
screen all limits have been
deactivated. The carriage can rotate until the
cylinders bottom out.
With the Joystick in the center position press the
Enter button (C).
D-171206CMA01C
Hillco Technologies, Inc.
28
Calibration
Before Proceeding:
-Park the combine on a level surface and
set the parking brake
-Read the setup instructions in the
Operator's Manual
-Press "Enter" to continue
A
Calibration
Joystick
Left/Right Clinometer
Carriage Angle Left Limit
Carriage Angle Right Limit
Fore/Aft Clinometer
B
Joystick Step 1 of 3
Joystick Output: 2452
With the joystick centered
press the enter button
C
Sept, 2022

Advertisement

Table of Contents
loading

Related Products for Hillco JS7020

This manual is also suitable for:

Js9020

Table of Contents