Left/Right Clinometer Calibration
(Level Zero Point)
From the Home Screen select Main Menu. Then
select Calibration Menu.
Using the up/down arrows, highlight Left/Right
Clinometer and press Enter (A).
Follow the directions on the screen. When the
combine is level side to side press Enter (B).
The screen will show the limit has saved.
Press ESC (C) to return to the calibration
menu.
D-171206CMA01C
C
Hillco Technologies, Inc.
30
Calibration
Joystick
Left/Right Clinometer
Carriage Angle Left Limit
Carriage Angle Right Limit
Fore/Aft Clinometer
A
Left/Right Clinometer
Place a level crossways on the cab floor
Manually lean the chassis until the cab
floor is level
Press Enter to save the level calibration
point
B
Left/Right Clinometer
Place a level crossways on the cab floor
Manually lean the chassis until the cab
Saved
floor is level
Press Enter to save the level calibration
point