4.2 Stand-by, Power Down and Audible Warning Control
To programme stand-by and power-down time and control the audible
warning:
Press the M key for 10 seconds, then release.
The display shows the symbol "L" (flashing) and the last set stand-by
time in minutes. (The stand-by time is the time after which the heater
temperature is automatically reduced to 60° C when the unit is left idle).
The stand-by time can be decreased or increased with the
Time can be set between 1 minute and 99 minutes with steps of
1minute or as "no" standby.
Press the M key again to store the new stand-by time and then the
display will flash with "P" and the current power-down time (in hours).
(The power-down time is the time after which the heater is switched off
automatically when the unit is left idle).
The power-down time can be decreased or increased with the
Power-down can be set between 1 hour and 24 hours with steps of 1
hour
Press the M key again to store the new power-down time and the
display will flash with "S" and the current audible warning setting.
The audible warning function can be enabled ("on") or disabled ("no")
with the
Press the M key again to store the audible warning function and this
will also exit from the programme menu.
The unit returns into "run mode" (see Chapter 5, Basic Functions, page
20) and the actual temperature of the heating platen is shown in the
display.