SET-UP

4.1 Set-Up Operating Mode

Turn on the 4s2 (switch located at back of the unit).
The display will show the software version for a couple of seconds and
then show the temperature to which the 4s2 is currently set. The unit is
delivered with the heater platen turned off. If this is the first time of
switching the unit on, the keypad will display "oFF". Otherwise, when
switched on, the unit will start to heat up to the last set temperature and
the LED light will flash whilst it is heating up.
To programme time and temperature settings:
Briefly press and release the M key
The display shows the last set sealing temperature (flashing)
The temperature can be decreased or increased using the
Temperature can be set between 120° C and 200° C with steps of 1° C or
to "oFF".
Press the M key again to store the new set temperature and then the
display will flash with "t" and the current sealing time (flashing).
The sealing time can be decreased or increased with the
Time can be set between from 0-1 second in 0.1 second increments
and from 1-10 seconds in 0.5 second increments.
Press the M key again to store the new sealing time value and this will
also exit from the programme menu.
The unit returns into "run mode" (see Chapter 5, Basic Functions, page
20) and the actual temperature of the heating platen is shown in the
display.