12.4.2.7
Network Adaptor 5 Installation (Optional)
1. Remove the Control Board Cover ⑤, then
connect the cable included with this adaptor to
the CN-CNT connector on the printed circuit
board.
Pull the cable out of the Tank Unit so that
there is no pinching.
If an Optional PCB has been installed in the
Tank Unit, connect to the CN-CNT connector
of the Optional PCB.
2. Insert a flat head screwdriver into the slot on
the top of the adaptor and remove the cover.
Connect the other end of the CN-CNT cable
connector to the connector inside the adaptor.
Slot
3. Pull the CN-CNT cable through the hole in the
bottom of the adaptor and re-attach the front
cover to the back cover.
Connector
CN-CNT cable
(Take care not to
pinch the cable)
4. Fix the Network Adaptor 5 to Network
Adaptor Holder.
Guide the cable as shown in the diagram so that
external forces cannot act on the connector in the
adaptor.
Connection examples:
Without Optional PCB
With Optional PCB
96
CN-CNT cable
CN-CNT cable
Network
Adaptor
Holder
Network
Adaptor
Holder