12.3.2 Install the Outdoor Unit
12.3.2.1
Installation Diagram
It is advisable to avoid more than 2 blockage directions. For better ventilation & multiple-outdoor installation,
please consult authorized dealer/specialist.
This illustration is for explanation purposes only.
(Anchor pitch)
After selecting the best location, start installation according to Installation Diagram.
1
Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm).
2
When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand
firmly with bolt or nails.
12.3.2.2
Disposal of Outdoor Unit Drain Water
When a Drain elbow 1 is used, please ensure to follow below:
-
the unit should be placed on a stand which is taller than 50 mm.
-
cover the ø20mm holes with Rubber cap 2 (refer to illustration below).
-
use a tray (field supply) when necessary to dispose the outdoor unit drain water.
If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommended
not to use the Drain elbow 1 and Rubber cap 2 , for the drain water freezes and the fan will not rotate.
Vinyl tape (Wide)
Saddle
Indoor/Outdoor connecting cable
- For WH-UXZ09KE5*, WH-UXZ12KE5* use 4-CORE WIRE
min 4.0mm
Type designation 60245 IEC 57 or heavier cord
ø6.35mm (1/4") Liquid refrigerant piping
ø12.7mm (1/2") Gas refrigerant piping
Check that the cables do not
touch the compressor, etc.
E
A
B
Rubber cap
2
2
Model
WH-UXZ09KE5*,
WH-UXZ12KE5*
Drain elbow
x 8
80
A
B
C
D
620
140
15
355
1
E
F
450
44
(Unit : mm)