installation

Clearances

Note: The clearances listed below are minimum distances unless otherwise stated.
installation
A major cause of chimney-related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Clearances CV60E
Clearance
The clearances listed below are Minimum distances unless otherwise stated:
A1: Mantel Height (min.)
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
A: From Floor (min.)
fireplace and vent system be installed only in accordance with these instructions.
B: Sidewall (on one side) min.
B1: Sidewall (on one side) min.
Clearance: single sided
C: Enclosure Width (min.)
A1: : Mantel Height (min.)
D: Mantel Depth (max.)
A: From Floor
E: Alcove Width
B: Sidewall (on one side)
F: Alcove Depth
C: Enclosure width
installation
G: Convection Air Outlet Opening Offset
D: Mantel Depth (max.)
Clearances CV60E
(min.)
E: Alcove Width
H: Convection Air Outlet
The clearances listed below are Minimum distances unless otherwise stated:
F: Alcove Depth
I: Framing Depth (min.)
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
G: Convection Air Outlet Opening O set
fireplace and vent system be installed only in accordance with these instructions.
J: Opening Height
H: Convection Air Outlet
K: minimum clearance to ceiling
I: Framing depth
Clearance: single sided
L: Chase Enclosure (min.)
A1: : Mantel Height (min.)
J:
Opening Height
A: From Floor
M:Clearance to Sprinkler Head (min.)
K: Minimum clearance to celing
B: Sidewall (on one side)
Hearth
L: Ceiling height
C: Enclosure width
** See mantel clearances chart in the manual.
M: Clearance to Sprinkler Head (Min.)
D: Mantel Depth (max.)
E: Alcove Width
Hearth
F: Alcove Depth
** See mantel clearances chart in this manual.
G: Convection Air Outlet Opening O set
H: Convection Air Outlet
*A minimum of 180 square
*
I: Framing depth
A minimum of 180 square
inches of open area, not
inches of open area, not
J:
Opening Height
lower than 0-2" from top
lower than 0-2" from top of
K: Minimum clearance to celing
of enclosure, required for
enclosure, required for all
L: Ceiling height
all installations.
installations
M: Clearance to Sprinkler Head (Min.)
Hearth
** See mantel clearances chart in this manual.
*
A minimum of 180 square
inches of open area, not
lower than 0-2" from top of
enclosure, required for all
installations
L
F
F
E
Alcove
Alcove
36 | City Series CV60E-1
36 ............................................. |City Series CV60E-1
28
|
City Series CV60E
28
|
City Series CV60E
Dimension
**
10-1/4" (260 mm)
8" (203 mm)
24" (610 mm)
Dimension
65-11/16" (1668 mm)
**
**
10 1/4" (260 mm)"
109-1/2" (2781 mm)
8" (203mm)
65 11/16" (1668mm)
35" (889 mm)
**
*0-2" (0-51 mm)
109.5" (2781mm)
*180 in
(1161 cm
2
2
35" (889mm)
20-5/16" (516 mm)
*0-2" (0-51mm)
18" (457 mm)
*180 square inches
1-3/4" (44 mm)
20-5/16" (516mm)
Dimension
Measured From:
81-1/4" (2064 mm)
**
Top of Fireplace Opening
18" (457 mm)
10 1/4" (260 mm)"
Bottom of Fireplace Opening
36" (914mm)
1 3/4" (44 mm)
8" (203mm)
Side of Fireplace Opening
0"
81 1/4" (2038 mm)
65 11/16" (1668mm)
Side of Fireplace Opening
36" (914mm)
**
109.5" (2781mm)
Sidewall to Sidewall (Minimum)
0"
35" (889mm)
Front to Unit (Maximum)
*0-2" (0-51mm)
*180 square inches
G
20-5/16" (516mm)
From back wall to chase front
18" (457 mm)
Bottom/Top of Fireplace Opening
1 3/4" (44 mm)
Top of chase to ceiling
81 1/4" (2038 mm)
From base of unit to ceiling
Perpendicular
from chase grill
36" (914mm)
0"
hearth required
L
G
H
A1
J
A1
A
B
J
A
E
Alcove
Measured From:
Top of Fireplace Opening
Bottom of fireplace opening
Side of fireplace opening
Side air outlet to side wall (min.)
Measured From:
Side of fireplace opening
Top of Fireplace Opening
Bottom of Fireplace Opening
Sidewall to sidewall (minimum)
Side of Fireplace Opening
Side of Fireplace Opening
Front to unit (maximum)
Max. offset from top of chase enclosure
Sidewall to Sidewall (Minimum)
)
Front to Unit (Maximum)
From back wall to chase front
Bottom/top of fireplace opening
Top of chase to ceiling
Flue Clearances to Combustibles
From back wall to chase front
Horizontal - Top
From base of unit/floor to top of enclosure
Bottom/Top of Fireplace Opening
Horizontal - Side
Perpendicular from chase grill
Horizontal - Bottom
Top of chase to ceiling
Vertical
No hearth required
From base of unit to ceiling
Passing through wall/
Perpendicular
from chase grill
floor/ceiling - when
hearth required
Note: This appliance uses 5" x 8" venting.
H
B
Chase grill
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
Flue Clearances to Combustibles
Passing through wall/
Horizontal - Top
floor/ceiling - when
Horizontal - Side
firestop is used.
Horizontal - Bottom
Vertical
Note: This appliance uses 5" x 8" venting.
Passing through wall/
floor/ceiling - when
Note: This appliance uses 5" x 8" venting.
3"
2"
2"
2"
1-1/2"
Caution Requirements
The top, back and sides of the fireplace are
defined by standoffs. The metal ends of
the standoff may NOT be recessed into
combustible construction.
Fire hazard is an extreme risk
Chase grill
if these clearances (air space) to
combustible materials are not adhered
to. It is of greatest importance that this
Sprinkler
fireplace and vent system be installed only
M
in accordance with these instructions.
Side view
3"
2"
2"
2"
3"
1-1/2"
2"
2"
2"
1-1/2"
H e a t W a v e
T h e
Duct Kit has different
clearance and framing
requirements, check the
HeatWave manual for
details.
Sprinkler
M
WARNING
Side view
Sprinkler
L
M
Chase grill
Side view