Advertisement

5: Operation
accurate, and it will not be possible to
determine if fluid levels are too low.
2. Ensure that a minimum clearance of 3 feet is
provided all the way around the machine to
allow exhaust gas to ventilate before operat-
ing the machine.
• Failure to ventilate hot exhaust gas can
result in improper functioning of machine
and the heat build-up can result in melting
of rubber and/or plastic components.
3. Check all oil and fluid levels in the engine and
compressor. Add oil and/or fluid if necessary.
4. Fill the fuel tank and drain any water from the
fuel/ water separator.
5. Check the dust collectors and clean if necessary.
6. Crack open one service line.
7. Turn the WARM-UP CONTROL control to
the START position.
• When the Single Axle Controller is initially
powered up, the system will initiate a "Self
Test" sequence to verify its operational integ-
rity and safety status. During this process, the
following actions will be performed.
1. Gauge pointers will move to the zero
position, then to half and full scale,
then back to zero, and finally to the
actual value reading.
2. The LCD display will turn on all its
segments for one second, off for one
second, and then display the Sullair
logo followed by the software prod-
uct number with revision level.
44
02250216-781 R02
Subject to EAR, ECCN EAR99 and related export control restrictions.
3. All warning lights will turn on for 2.5
seconds and then turn off, then set
to the actual indicator state.
8. Toggle the START/ON/OFF switch to the ON
position.
9. Wait for the status message on the display to
switch to Ready.
10. Momentarily toggle the START/ON/OFF to
the START position and release the switch to
engage the starter.
11. After 30 seconds, turn the WARM-UP CON-
TROL from START to RUN to put the com-
pressor in full operation.
12. Close all doors to maintain proper noise
level.

5.4 Shutting down the compressor

1. Close the service valves and run the com-
pressor for approximately five minutes to
allow the compressor to cool down.
2. Toggle the engine switch to the OFF position
after five minutes.
If an emergency shutdown is required, immedi-
ately press the emergency stop button.
Do not use the emergency stop button in place
of the normal shutdown procedure described
above.
185 T4F Kubota User Manual
WARNING