Entrapment; Implementation Of Lockout/Tagout - Sullair 185CFM User Manual

Portable air compressor
Hide thumbs Also See for 185CFM:
Table of Contents

Advertisement

2: Safety
Keep lift operator in constant attendance whenever
I.
compressor is suspended.
J. Set compressor down only on a level surface capa-
ble of supporting at least its net weight plus an addi-
tional 10% allowance for the weight of water, snow,
ice, mud, stored tools, and/or equipment.
K. If the compressor is provided with parking brakes,
make sure they are set, and in any event, block or
chock both sides of all running wheels before disen-
gaging the lifting hook.

2.10 Entrapment

Make sure all personnel are out of compressor
A.
before closing and engaging enclosure doors.
If the compressor is large enough to hold a man and
B.
if it is necessary to enter it to perform service adjust-
ments, inform other personnel before doing so, or
else secure the access door in the open position to
avoid the possibility of others closing and possibly
latching the door with personnel inside.

2.11 Implementation of lockout/tagout

The energy control procedure defines actions necessary
to lockout a power source of any machine to be repaired,
serviced or set-up, where unexpected motion, or an elec-
trical or other energy source, would cause personal injury
or equipment damage. The power source on any
machine shall be locked out by each employee doing the
work except when motion is necessary during setup,
adjustment or trouble-shooting.
A. The established procedures for the application of
energy control shall cover the following elements and
actions and shall be initiated only by Authorized Per-
sons and done in the following sequence:
1. Review the equipment or machine to be
locked and tagged out.
2. Alert operator and supervisor of which
machine is to be worked on, and that power
and utilities will be turned off.
3. Check to make certain no one is operating
the machine before turning off the power.
4. Turn off the equipment using normal shut-
down procedure.
5. Disconnect the energy sources:
a. Air and hydraulic lines should be bled,
drained and cleaned out. There should
be no pressure in these lines or in the
8
02250216-781 R02
Subject to EAR, ECCN EAR99 and related export control restrictions.
reservoir tanks. Lockout or tag lines or
valves.
b. Any mechanism under tension or pres-
sure, such as springs, should be
released and locked out or tagged.
c. Block any load or machine part prior to
working under it.
d. Electrical circuits should be checked with
calibrated electrical testing equipment
and stored energy and electrical capaci-
tors should be safely discharged.
6. Lockout and/or Tagout each energy source
using the proper energy isolating devices
and tags. Place lockout hasp and padlock or
tag at the point of power disconnect where
lockout is required by each person perform-
ing work. Each person shall be provided with
their own padlock and have possession of
the only key. If more than one person is
working on a machine each person shall affix
personal lock and tag using a multi-lock
device.
7. Tagout devices shall be used only when
power sources are not capable of being
locked out by use of padlocks and lockout
hasp devices. The name of the person affix-
ing tag to power source must be on tag along
with date tag was placed on power source.
8. Release stored energy and bring the equip-
ment to a "zero mechanical state".
9. Verify Isolation: Before work is started, test
equipment to ensure power is disconnected.
B. General Security
1. The lock shall be removed by the "Autho-
rized" person who put the lock on the
energy-isolating device. No one other than
the person/persons placing padlocks and
lockout hasps on power shall remove pad-
lock and lockout hasps and restore power.
However, when the authorized person who
applied the lock is unavailable to remove it
his/her Supervisor may remove padlock/pad-
locks and lockout hasps and restore power
only if it is first:
a. verified that no person will be exposed to
danger.
b. verified that the "Authorized" person who
applied the device is not in the facility.
c. noted that all reasonable efforts to con-
tact the "Authorized" person have been
185 T4F Kubota User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

185

Table of Contents