For Your Safety; Unit Features; Function Description - Pilz PSEN 2.1a-20 Operating Manual

Table of Contents

Advertisement

PSEN 2.1a/b-20

For your safety

Unit features

}
The actuator PSEN 2.1-20 belongs to the safety switch.
}
Coded actuator
}
Safety switch with cable (5 m/ 10 m)
}
2 safety contacts (reed contacts - N/C and N/O)
}
Design: Square
}
Operation Magnetic
}
Switching voltage 24 VDC
}
Series connection via PSEN i1 interface
}
ECOLAB tested

Function description

If the actuator is within the response range (safety gate closed), the safety contacts on the
safety switch will be switched. The N/O contact is closed and the N/C contact is opened.
The safety switch is designed for applications in series connections.
Operate the PSEN 2.1a/b-20 in conjunction with the following components:
}
Actuator PSEN 2.1-20 (see
}
Interface PSEN i1 (see
}
a connected evaluation device (see
devices [
Operating Manual PSEN 2.1a/b-20
21205-EN-08
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If substitute actuators are used, these must be installed as described
under
Installation [
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
Order reference [
Order reference [
10]).
12].
16]),
17]) and
Requirements and connection to evaluation
| 7