Door closer with hold open arms

Advertisement

A
A1) Select closer mounting position based on the maximum door opening, as listed below
Note: For ADA applications, select the 160ϒ position
B
B1) Prep door and frame
Note: 3/32" pilot holes are required when Self Tapping Screws are being used
Note: If machine screws are being used, use a drill #16 (.177) and a #12-24 tap
B2) Install closer body onto the door
B3) Install Foot & Rod Assembly onto the frames
DIM. "B"
DIM. "A"
1
1
"
4
1"
C OF HINGE PIVOT
L
RIGHT HAND DOOR ILLUSTRATED. SAME DIMENSIONS APPLY FOR LEFT HAND DOOR.
C
C1) Install main arm on the closer with the index mark on the spindle aligning with the # 2 on the main arm (as shown)
D
Attach hold open foot to frame with adjusting nut facing down for left hand door or up for right hand door, as illustrated below
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company.
2
All rights reserved. Reproduction in whole or in part without the express written permission
of Sargent Manufacturing Company is prohibited.
A7140F

STANDARD APPLICATION

#12 X 1 1/2 SCREWS OR
#12-24 X 5/8 FLAT HEAD
2-1/2"
MACHINE SCREW*
DOOR CLOSER
11
"
1
8
*SEE PAGE 8 FOR MORTISE NUTS
RIGHT HAND DOOR
INDEX MARK
ON SPINDLE
POSITION OF
MAIN ARM WHEN
ASSEMBLING
TO SPINDLE
NUT FACES UP
RIGHT HAND
DOOR SHOWN
MAXIMUM DOOR
TOP OF DOOR
7
"
8
2
9
"
16
FACE OF DOOR
FRAME
NUT FACES DOWN
LEFT HAND
DOOR SHOWN
DIM. A
DIM. B
OPENING
120ϒ
7 1/2"
13 1/4"
160ϒ **
4 1/4"
10"
**If Butt, Frame and Wall Conditions Permit
Door Will Open 180ϒ
FRAME
RAILS TO 1
3
" MAY BE
4
USED PROVIDED FRAME
DOES NOT PROJECT
BEYOND FACE OF DOOR
2
5
"
16
FRAME
2
5
" MIN
8
TOP RAIL

Advertisement

loading

This manual is also suitable for: