Download Print this page

Assa Abloy SARGENT 1431 Series Instructions Manual page 8

Door closer with hold open arms

Advertisement

FINAL ADJUSTMENT AND REGULATING PROCEDURE
Minimum recommended door closing time is 6 Seconds for
doors opened to 90 degrees.
Use 1/8" hex (Allen) wrench to adjust valves as needed.
Closing and latching speeds:
Turn valves clockwise to slow down or counterclockwise to
speed up door movement.
Backcheck:
To regulate the intensity of back check action, turn valve clockwise
to increase or counterclockwise to decrease checking.
CAUTION: Set valve for slight cushioning effect; closer can be
damaged if the checking action is too abrupt. Never use
the backcheck as a door stop. Always use a door stop to stop
the door.
Delayed action feature (Optional feature on some models):
"Delayed action" provides slow door closing through the
delayed action range. Turn valve clockwise to slow down or
counterclockwise to speed up door movement.
NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT
DOOR WIDTH
1431 DOOR CLOSER
(INCHES)
TURN nut 1-3
24-30
30-36
FACTORY SET
36-42
TURN nut 1-4
42-48
TURN nut 7-9
Adjustment hold open arm
Slight tightening or loosening of hold
open nut changes holding position of door.
Note: To protect wall, trim and closer, use a door stop
located 10° beyond hold open position but not beyond
the max. door opening shown on instructions.
HOLD
OPEN
NUT
INSTALL COVER AS FOLLOWS:
FOR STANDARD AND PARALLEL ARM APPLICATION
• Screw short cover screw (#8-32 X 5/16) into top of case
approximately 2 turns
• Assemble plastic support and long cover screw (#8-32 X 1 1/4)
into bottom of case approximately 2 turns
• Hold support against case (approximately 2 turns)
between flange and screw head
• Position cover on closer and tighten screws
RIGHT HAND
ILLUSTRATED
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company.
8
All rights reserved. Reproduction in whole or in part without the express written permission
of Sargent Manufacturing Company is prohibited.
A7140F
Adjusting door
to close due to
high draft
conditions may
exceed ADA
standards.
Consult local
ordinances
when fire doors
are involved
USE 15/16"
COVER
WRENCH TO
ADJUST NUT
DRILL 1/4" DIA.
HOLE FOR MOUNTING SCREWS
GAP
SHORT COVER SCREW
PLASTIC SUPPORT AND
LONG COVER SCREW
PLACE IN UNUSED OPENING
FRAME
UNREINFORCED
DOOR
FOR TOP JAMB APPLICATION
• Assemble plastic support and long cover screw (#8-32 X 1 1/4")
into top of case approximately 2 turns
• Screw short cover screw (#8-32 X 5/16") into bottom of case
approximately 2 turns
• Slide cover into gap between flange and screw head. Position cover
on closer and tighten screws
INSERT IS REMOVABLE.
INSERT IS REMOVABLE. PLACE IN UNUSED OPENING
1. For top jamb and corner bracket
applications: The door closer foot
will be attached to the door in a
manner similar to that shown for
mounting the closer body.
DOOR
STOP
2. The appropriate mortise nuts
MORTISE
and screws will be suppled based
NUT HEAD
on door thickness.
DRILL
Door construction must provide a
3/8" DIA.
bridge type reinforcement to prevent
HOLE FOR
the door rail from collapsing when
MORTISE
NUT BODY
through-bolts are tightened.
PLASTIC SUPPORT AND
LONG COVER SCREW
SHORT COVER SCREW

Advertisement

loading

This manual is also suitable for: