AIR RECEIVER
The air receiver (1) is tested according to official
standards. Regularly have inspections carried out in
conformity with local regulations.
Daily drain condensate.
SAFETY VALVE
All adjustments or repairs are to be done by
an authorized representative of the valve
supplier,
see
section
precautions.
Following checks must be carried out on the safety valve
(2):
•
A check of the opening of the lifting gear, twice a
year.
This can be done by screwing the cap of the valve
anti-clockwise.
•
A check of the set pressure once a year according to
the local regulations. This check cannot be done on
the compressor and must be carried out on a proper
test bench.
- 56 -
Specific
safety