Table 34. NVMe-oF SubSystem Settings screen details
Option
NVMe-oF SubSystem n (n = 1 to 4)
NVMe-oF SubSystem n Settings (n = 1
to 4)
Table 35. NVMe-oF SubSystem n Settings
Option
Interface
Transport Type
Protocol
VLAN
VLAN Id
VLAN Priority
Retry Count
Timeout
DHCP
Host IP Address
Host Subnet Mask
Host Gateway
NVMe-oF subsystem info via DHCP
NVMe-oF subsystem NQN
NVMe-oF subsystem Address
NVMe-oF subsystem Port
NVMe-oF subsystem NID
NVMe-oF subsystem Controller ID
Security
Authentication Type
Securitykeypath
42
Pre-operating system management applications
Description
Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Description
NIC interface used for NVMe-oF connections.
This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.
Enables or disables VLAN for this NVMe-oF connections. This option is set to
Disabled by default.
Specifies the VLAN Id for this NVMe-oF connection. This option is set to 1 by
default.
Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by
default.
Specifies the retry count for this NVMe-oF connection. This option is set to 3 by
default.
Specifies the time out for this NVMe-oF connection. This option is set to 10000 by
default.
Enables and disables the DHCP for this NVMe-oF connection. This option is set to
Disabled by default.
Specifies the Host IP Address for this NVMe-oF connection.
Specifies the Host Subnet Mask for this NVMe-oF connection.
Specifies the Host Gateway for this NVMe-oF connection.
Enables and disables the NVMe-oF subsystem's DHCP for this connection. This
option is set to Disabled by default.
Specifies the NVMe-oF subsystem's NQN for this connection.
Specifies the NVMe-oF subsystem's IP address for this connection.
Specifies the NVMe-oF subsystem's port for this connection. This option is set to
4420 by default.
Specifies the NamespaceID (NID) for this NVMe-oF connection.
Specifies the NVMe-oF subsystem's Controller ID for this connection. This option
is set to 0 by default.
Enables or disables the security option for this NVMe-oF connection. This option is
set to Disabled by default.
Specifies the authentication type for this NVMe-oF connection. This option is set
to None by default.
Specifies the Securitykeypath for this NVMe-oF connection.