SAFETY OPERATION
Emergency stop
All equipment is connected to the general emergency system for PR350H.
When an emergency-stop device is activated, all components located in the emergency zone will be disconnected from
their power source.
Machine safety
There are machine safety measures in the following areas:
Extruder unit
•
Extruder plate changer
•
In these areas, protective covers are in place.
The covers are provided with locking screws to deter removal.
Required performance level PLr = c Implemented in category = Cat3.
There is a danger of congelation/frost bite by touching machine parts cooled down by dry ice.
To prevent congelation the entire machine enclosure is provided with locks that require special tools to open.
Liquid CO2 Leakage
If liquid CO
is leaking from any point of the CO
2
leakage and repair.
Stop Production
1.
The machine is stopped by pressing the "Start / Stop" button.
NOTE: This will activate the shutdown procedure.
2.
The CO
valve on the machine inlet will automatically close. It is recommended to close the manual valve on the
2
mounting kit before leaving the machine unused for a longer period of time.
3.
Cut off the main electric supply.
NOTE:
Do not shut off the main switch on the cabinet inside the machine before the inlet CO
pressure can be checked on the "Process values" page.
Daily checkup before start-up
1.
Check the oil level in the sight glass.
2.
Check the pipe system for leaks.
3.
Check the operation time since service intervals.
pipe system, the CO
supply must be stopped immediately. Localize the
2
2
PR120H
User's manual
pressure is ZERO. The CO
2
Version:
1
Page:
9 of 14
Date:
2023.01.19
2
Need help?
Do you have a question about the PR350H and is the answer not in the manual?