Cold Jet PR350H Pre-Installation page 16

Dry ice manufacturing system - pelletizers
Hide thumbs Also See for PR350H:
Table of Contents

Advertisement

Pre-Installation Guidelines & Checklist
Hydraulic Oil (Initial Filling)
The machine will be delivered without hydraulic oil in accordance with the ADR Dangerous
Goods by Road regulations or similar for sea and air transportation. The owner/operator is
responsible for retaining a local supplier and having the oil on-site prior to the commissioning
of the machine.
Instruction for the initial filling are below. The owner/operator can fill the tank or have the Cold
Jet technician fill the tank prior to the commissioning and start up of the machine.
The approximate volume and oil type is listed in the table below:
Hydraulic Oil (Initial Filling)
Hydraulic Reservoir Capacity (Max Filling)
Oil Grade/Type - Standard Technical
Oil Grade/Type - Food Grade / FDA
Filling the Oil Tank
1. Remove the air filter by unscrewing it from the hydraulic tank to access the oil filling
port.
2. Remove the oil filter by unscrewing it.
3. Fill the tank with the appropriate type of oil until max level is observed on the tank level
indicator.
4. Reinstall the oil filter and air filter onto the oil filing port .
12
PR120H
PR350H
80 l (21.1 gal)
180 l (47.6 gal)
Mobile DTE 10 Excel 46
Mobil DTE FM 46
PR750H
200 l (52.8 gal)