2.2 Hardware Installation Procedure

Please follow the instructions below to set up the programmer hardware:
#
Action
1
Remove programmer from all packaging
2
Ensure you are wearing an ESD strap and/or
you are working in an ESD protected
environment.
3
Remove all four screws from the back of the
programmer
4
Remove programmer cover
5
Select Power Supply Scenario
Please refer to section 3 for a full explanation
of which is the correct way of powering the
programmer for your application.
6
Check J5 – Firmware Update Jumper - is
NOT fitted
EPSILON5 MKII Programmer - User Guide V1.12 – 1
Observation
You will need the following items:
Epsilon5 programmer
10-way ISP Ribbon Cable
Jumper Link
You will find a 'Jumper Link' and the plastic feet
for the programmer inside a small plastic bag.
The screws are supplied in a small plastic bag
when you open the programmer packaging for
the first time.
You need to select how the programmer is to be
powered. The programmer can be powered from
the Target System or from an External Power
Supply via the DC Jack Connector. The power
supply selection is set up via the Jumper Link
J9.
Where is Jumper Link J9?
You can find Jumper Link J9 next to the 'J7
Atmel 10-way ISP Header'
Jumper J9 Fitted:
Target Vcc is connected directly to
the Programmer CON1 Vcc (same as
plugging in the Jack Socket).
In this mode, the programmer will
power from the Target system or the
Target System can power the
Programmer.
The supply voltage must be between
3.0 and 5.0V.
Jumper J9 Not Fitted:
Target Vcc is independent (not
connected) to the programmer Vcc.
In this mode you will need to supply
power at 3.0 – 5.0V via the DC Jack
Connector (CON1)
This jumper can be found next to the 9-
way D connector.
It must NOT be fitted during normal
operation of the programmer.
It should only be fitted when the
st