Channel Coupling - UNI-T UTG2122B User Manual

Function/arbitrary waveform generator
Hide thumbs Also See for UTG2122B:
Table of Contents

Advertisement

8.
Amplitude upper limit
Select Amplitude upper limit, to set the limit value.
9.
Amplitude lower limit
Select Amplitude lower limit, to set the limit value.

2.5.2 Channel coupling

Menu
Sub menu
Channel coupling
ON/OFF
Parameter
coupling
Signal tracking
Note: when you select parameter coupling,
signal tracking,
appears instead.
1.
Parameter coupling
Coupling of frequency, amplitude or phase. You can set the frequency deviation/ frequency ratio,
amplitude deviation/ratio or phase deviation/ratio of these two channels. The parameters of them are
the reference for each other. When you change the parameter of one channel, the parameter of the
other will adjust accordingly and keep the same deviation/ratio as the reference channel.
Deviation:=CH2-CH1;Ratio=CH2:CH1
Select Utility
Channel coupling, the status is OFF, then select Channel coupling
Parameter coupling in this order, you can set up parameter coupling: frequency, amplitude and
phase
Note: In frequency coupling, you can select OFF, deviation or ratio.
2.
Signal tracking
Select Utility
Channel coupling, the status is OFF, then select Channel coupling
Signal tracking in order, set up phase deviation. When you set the deviation, and the parameter of
one channel, the other one will adjust accordingly.
UTG2000B Series
Setting
Note
ON/OFF
Only when the status is ON, the
following menu can be opened.
Frequency
coupling,
amplitude
coupling, phase
coupling
Phase deviation
appears at the lower left corner. When you select
ON
Coupling type
ON
Coupling type
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Utg2000b seriesUtg2062bUtg2082Utg2082b