Gating Mode - UNI-T UTG2122B User Manual

Function/arbitrary waveform generator
Hide thumbs Also See for UTG2122B:
Table of Contents

Advertisement

3.3.3 Gating mode

Press soft function keys Type → Gated successively on the interface to enter gating mode. In
mode of gating pulse train, trigger source, trigger output, trigger edge, burst period (period of pulse
train) and recurring number will be automatically hidden in parameter list. As only external trigger
source can be used, waveform generator is triggered according to hardware of external digital
modulation interface (FSK Trig connector) of back panel. When polarity is positive and trigger input
signal is at high level, a continuous waveform is output; when trigger input signal is at low level, the
current waveform period is finished first and then stop at the level corresponding to initial phase of
the waveform selected. For noise waveform, when gated signal is spurious, output will be
immediately stopped. Polarity can be changed with multi-functional knob and direction key on the
interface for selecting gating mode (as shown in the figure below) or by pressing soft key Param →
Polarity .
Figure 3 -49 Select gating mode
Infinite mode
Press soft function keys
Type
→ Infinite
successively on the interface for starting pulse
function to enter infinite mode. In mode of infinite pulse train, burst period (period of pulse train)
and recurring number will be automatically hidden in parameter list. Infinite pulse train amounts to
infinite cycle index of waveform. The signal generator outputs continuous waveform when receiving
trigger signal. The trigger source of pulse train can be internal, external or manual in this mode. To
change it, you can use multi-functional knob and direction key on the interface for selecting type of
pulse train (as shown in the figure below) or press soft function key Param → Source
102
UTG2000B Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Utg2000b seriesUtg2062bUtg2082Utg2082b

Table of Contents