Lenovo 7D9P Manual page 14

Hide thumbs Also See for 7D9P:
Table of Contents

Advertisement

Table 2. Events organized by severity (continued)
Message String
Event ID
FQXSPEM4013I
Battery error was detected by RAID controller. The battery unit needs
replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
FQXSPEM4014I
The RAID controller has problem with the battery. Please contact
technical support to resolve this issue.([arg1],[arg2],[arg3],[arg4],
[arg5])
FQXSPEM4015I
The RAID controller detected unrecoverable error. The controller
needs replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
FQXSPEM4016I
The RAID controller detected one or more problems. Please contact
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4],
[arg5])
FQXSPEM4017I
The RAID controller detected one or more possible configuration
changes within the subsystem. Please check the drive LED status. If
necessary, contact technical support for additional assistance.([arg1],
[arg2],[arg3],[arg4],[arg5])
FQXSPEM4018I
Enclosure/Chassis issue detected with one or more units. Please
check the enclosure/chassis units to repair the problem.([arg1],[arg2],
[arg3],[arg4],[arg5])
FQXSPEM4019I
Connectivity issue detected with the enclosure/chassis. Please check
your cable configurations to repair the problem.([arg1],[arg2],[arg3],
[arg4],[arg5])
FQXSPEM4020I
Fan problem detected with the enclosure/chassis. Please check the
enclosure/chassis unit fan for correct operation.([arg1],[arg2],[arg3],
[arg4],[arg5])
FQXSPEM4022I
Enclosure/Chassis power supply has problem. Please check the
enclosure/chassis unit power supply for correct operation.([arg1],
[arg2],[arg3],[arg4],[arg5])
FQXSPEM4023I
One or more virtual drive are in abnormal status that may cause
unavailable virtual drive. Please check the event logs and if events are
targeted to the same disk then replace the drive. If necessary, contact
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4],
[arg5])
FQXSPEM4024I
The RAID controller detected one or more possible configuration
problem within the subsystem. Please check the event logs and if
events are targeted to the same disk then replace the drive. If
necessary, contact technical support for additional assistance.([arg1],
[arg2],[arg3],[arg4],[arg5])
FQXSPEM4025I
One or more virtual drive have problem. Please contact technical
support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5])
FQXSPEM4026I
Drive error was detected by RAID controller. Please contact technical
support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5])
FQXSPEM4027I
Drive error was detected by RAID controller. Please check the event
logs and if events are targeted to the same disk then replace the drive.
If necessary, contact technical support for additional assistance.
([arg1],[arg2],[arg3],[arg4],[arg5])
FQXSPEM4028I
The port [arg1] of PCIe device [arg2] at [arg3] has link [arg4].
FQXSPEM4029I
All PCIe slots on [arg1] may not be functional based upon your current
CPU population.
10
ThinkSystem SD665 V3 Messages and Codes Reference
Severity
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sd665 v3

Table of Contents