Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0508
User Action:
Reboot the system. If the problem still exist, press F1 or use LXPM to do XCC FW update.
• FQXSPUN0017I: Sensor [SensorElementName] has transitioned to normal state.
This message is for the use case when an implementation has detected a Sensor transition to the normal
state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0518
User Action:
Information only; no action is required
• FQXSPUN0018J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0520
User Action:
Please check event log of XClarity Controller to investigate the identified device for enhancement.
• FQXSPUN0019M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Please check XCC web GUI to see the identified error.
2. Check system event log to fix the error.
3. If the problem still exist, please contact Lenovo service.
.
Chapter 2