Cleaning The Airless Spray Gun; Servicing; General Servicing; High-Pressure Hose - WAGNER Brillux SUPER FINISH 23 PRO SELECT Operating Manual

Airless high-pressure spraying unit
Table of Contents

Advertisement

Available languages

Available languages

SuperFinish 23 Pro Select
8.4

CLEANING THE AIRLESS SPRAY GUN

1. Rinse the Airless spray gun with a suitable cleaning agent
under lower operating pressure.
2. Clean the tip thoroughly with a suitable cleaning agent so
that no suitable coating material rests remain.
3. Do not store the tip in solvent because this reduces the
durability considerably.
4. Clean the outside of the Airless spray gun thoroughly.
1
Insertion filter in the Airless spray gun
1. Unclip the top of the trigger guard (1) from the gun head.
2. Using the bottom of the trigger guard as a wrench, loosen
and remove the handle assembly (2) from the gun head.
3. Pull the old filter (3) out of the gun head. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten
with the trigger wrench.
6. Snap the trigger guard back onto the gun head.
9
9.1
Minimum check before every startup:
1. Check the high-pressure hose, spray gun with rotary joint,
2. Check whether the pressure gauge can be read.
Check at periodical intervals:
3
1. Check inlet and outlet valve according wear. Clean it and
2. Check all filter inserts (spray gun, suction system) clean it
2
9.2
Inspect the high-pressure hose visually for any notches or
bulges, in particular at the transition in the fittings. It must be
possible to turn the union nuts freely. A conductivity of less
than
1 MΩ must exist across the entire length.

SERVICING

GENERAL SERVICING

We strongly recommend having an annual
check carried out by technicians for safety
reasons. Please observe all the applicable na-
tional regulations.
power supply cable with plug for damage.
replace worn out parts.
and replace if necessary.

HIGH-PRESSURE HOSE

Have all the electric tests carried by the Wag-
ner Service.
The risk of damage rises with the age of the
high-pressure hose.
Wagner recommends replacing high-pres-
sure hoses after 6 years.
CLEANING THE UNIT / SERVICING
EN
45

Advertisement

Table of Contents
loading

Table of Contents