Problem solving guide
Problem
F and a number
appear in the
display.
F 10
F 44
F 195
F 55
F 94
68
Possible cause
The suction tube in the
water container
– is not fitted correctly
– is not positioned
vertically
Communication fault
The maximum operating
duration for one of the
functions has been
exceeded and safety
switch-off has been
triggered.
No water intake:
The float switch on the
left-hand side in the
water container is stuck.
Remedy
Connect it properly and make
sure it is vertical:
Switch the appliance off. Wait a
few minutes and switch it back
on again.
If the fault message is still
displayed, call the Service
Department.
The appliance will be ready for
use again after it has been
switched off and then back on
again.
Release the float switch.
If the problem occurs again,
contact the Service department.