Use elastic spacers/liners when these are provided with
the grinding accessory.
Make sure that the application tools are mounted in
accordance with the manufacturers instructions. The
mounted application tools must be able to rotate freely.
Incorrectly mounted application tools can become
loose during operation and be thrown from the
machine.
Handle grinding accessories carefully and store them
according to the manufacturer's instructions. Damaged
grinding accessories can develop cracks and burst dur-
ing operation.
When using application tools with a threaded insert,
take care that the thread in the application tool is long
enough to hold the spindle length of the power tool. The
thread in the application tool must match the thread on
the spindle. Incorrectly mounted application tools can
loosen during operation and cause injuries.
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Beware of any concealed electric cables, gas or water
conduits. Check the working area before commencing
work, e. g. with a metal detector.
Use a stationary extraction system and frequently blow
out the ventilation slots. When working metal under
extreme operating conditions, it is possible for conduc-
tive dust to settle in the interior of the power tool. The
total insulation of the power tool can be impaired.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective.
Always work with the auxiliary handle. The auxiliary
handle ensures reliable guiding of the power tool.
Never look or stare into the light of the power tool's
lamp from a short distance. Never point the light of the
lamp into the eyes of other persons in close vicinity.
The radiation produced by the lamp can be harmful for
the eye.
After working gypsum-containing materials: Blow out
the ventilation openings of the power tool and the
switch element with dry and oil-free compressed air.
Otherwise, gypsum-containing dust can settle in the
power tool housing and switch element, which can
harden in connection with humidity. This can impair the
switching mechanism.
Use and handling of the battery (battery pack).
These safety warnings apply only for 18V FEIN AMP-
Share Li-ion batteries.
Use the battery only in AMPShare partner products. 18V
batteries marked with AMPShare are fully compatible
with the following products:
– All products of the FEIN-18V-AMPShare system
– All 18V products from AMPShare partners.
When working with and charging incorrect, damaged,
repaired or reconditioned batteries, imitations or other
brands, there is danger of fire and/or explosion.
Observe the battery recommendations in the operating
instructions for your product. Only in this way can the
battery and the product be operated safely, and the bat-
teries are protected from dangerous overload.
Only charge the batteries with chargers recommended
by FEIN or one of the AMPShare partners. A charger that
is suitable one type of battery pack may create a risk of
fire when used with another battery pack.
The battery is supplied partially charged. To ensure full
battery capacity, completely charge the battery in the
battery charger before using for the first time.
Store batteries out of the reach of children.
Batteries must not be disassembled, opened or reduced
in size. Do not subject batteries to mechanical impact
or shock. Hazardous vapours and fluid can escape in
case of damage and improper use of the battery. The
vapours can irritate the respiratory system. Liquid
ejected from the battery may cause skin irritations or
burns.
In case of skin contact with battery fluid, rinse immedi-
ately with plenty of water. In case of eye contact with
battery fluid, wash out the eye with clean water and
immediately seek a doctor for treatment!
When the battery fluid has come into contact with
objects close by, check the respective components.
Avoid skin contact by wearing protective gloves. Clean
the parts with dry household paper or replace the parts
if necessary. Escaping vapours can irritate the respira-
tory system. Liquid ejected from the battery may cause
skin irritations or burns.
Do not short-circuit the battery. Keep the battery not
being used away from paper clips, coins, keys, nails,
screws or other small metal objects, that can make a
connection from one terminal to another. Shorting the
battery terminals together may cause burns or a fire.
The battery can be damaged by sharp objects such as
nails or screwdrivers or by external force. An internal
short-circuit may occur and the battery can burn,
smoke, explode or overheat.
Never maintain damaged batteries. Any maintenance of
batteries should be performed only by the manufac-
turer or by authorised after-sales service centers.
Protect the battery against heat, e.g., against
continuous intense sunlight, fire, debris, water,
max.50°C
and moisture. Danger of explosion and short-
circuiting.
Operate and store the battery only at ambient tempera-
tures between -20 °C and +50 °C. As an example, do not
leave the battery in a vehicle in summer. At tempera-
tures < 0 °C, machine-specific performance restrictions
are possible.
Charge the battery only at ambient temperatures
between 0 °C and +35 °C. Charge the battery via USB
connection only at ambient temperatures between
+10 °C and +35 °C. Charging the battery outside the
temperature range may damage the battery or increase
the risk of fire.