SMA Solar Technology AG
Result
☑ If the stranded wire is not visible in the
chamber, the cable is not correctly
positioned.
4. Push the threaded joint up to the thread and screw into place with a torque of 2 Nm.
☑ The DC connectors are assembled and can now be connected to the inverter as described in
section 5.4.4 "Connecting the PV Array (DC)" (page 33).
Installation Manual
Measure
• Loosen the clamping bracket. To do so,
insert a 3.5 mm screwdriver into the
clamping bracket and lever it out.
• Remove the cable and go back to step 1.
SMC46-60A-IA-IEN120471
Electrical Connection
31