5.2 Fuse replacement 
 
 IMPORTANT! Disconnect power to the appliance! 
 Remove the cover.  
 Disconnect the regulator.  
 Remove the regulator cover.  
 Remove the fuse (T3, 15AH250V). 
 
5.3 FAQ 
 
Where should my water 
treatment system be 
positioned with respect 
to the heating system? 
Is it possible to improve 
temperature 
performance? 
 
5.4 Modification of the maximum setpoint temperature 
 Turn off the regulator (the "on" indicator light goes off, the pool water temperature is displayed). 
 Simultaneously press and hold 
 Press  . 
 Then enter the value "80" using the 
 Press   to confirm this code, "PA" is displayed. 
 Simultaneously press and hold the 
 Press 
 to scroll through each parameter until "r2" is displayed. 
 Press  , the current value of the parameter "r2" is displayed.  
 Press 
 or 
 to modify the maximum setpoint value.  
 Press   to confirm this new value. 
 Simultaneously press and hold 
 
6. Product registration 
 
Register your product using our website:  
- you will be among the first to be informed of new Zodiac products and special offers, 
- You can help us to constantly improve our product quality. 
 
 
7. Conformity certificate 
 
Z.P.C.E. declares that the following products or ranges: 
 Special swimming pool heater: Red Line + 3‐6‐9‐12 
 
are in compliance with the provisions of: 
 the ELECTROMAGNETIC COMPATIBILITY directive 89/336/EEC 
 the LOW VOLTAGE directive 73/23/EEC 
H03609‐00.B1.EN – 2012/01
The  water  treatment  system  (chlorinator,  salt  chlorinator,  etc.)  must  be  installed 
preferably  downstream  from  the  appliance  (see  installation  §2.2),  and  must  be 
compatible with the latter (check with the manufacturer) 
protect the pool with a cover (floating cover, roller cover, etc.), to avoid heat loss 
Check that 
during the heating phase, water flow must be continuous (24/24) 
filtration 
to  maintain  the  temperature  throughout  the  season,  allow  for 
time is 
"automatic" flow of at least 12 hours/day (the longer automatic flow 
sufficient  
is used, the more time the appliance will have to function and to heat 
the water) 
 and 
 for 5 seconds, "PA" is displayed. 
 or 
 and 
 and 
 for 5 seconds to return to the pool water temperature display. 
Australia – New Zealand 
South Africa 
Europe and rest of the world 
 
 keys (access code to the settings menu). 
 keys for 5 seconds. 