DTC
P0652
Sensor Reference Voltage "B" Circuit Fault
P0657
Actuator Supply Circuit Voltage 1 Open (HSD 1)
P0658
Actuator Supply Voltage 1 (HSD1) Low
P0659
Actuator Supply Voltage 1 (HSD1) High
P0702*
Transmission Control Hardware Not Determined
P0703
Brake Switch Circuit Malfunction
P0708
Transmission Range Sensor Circuit High Input
Transmission Fluid Level Sensor Circuit – Low
P070C
Input
Transmission Fluid Level Sensor Circuit – High
P070D
Input
Transmission Fluid Temperature Sensor Circuit
P0711
Performance
Transmission Fluid Temperature Sensor Circuit
P0712
Low Input
Transmission Fluid Temperature Sensor Circuit
P0713
High Input
P0715
Turbine Shaft Speed Sensor Circuit
P0716
Turbine Shaft Speed Sensor Circuit Performance
P0717
Turbine Shaft Speed Sensor Circuit No Signal
P071A
Neutral at Stop Input Failed On
P071D
General Purpose Input Fault
P0720
Output Shaft Speed Sensor Circuit
Description
PA-1652 Operator's Manual H3-45 Coach
Allison Transmission Other Features C-11
CHECK
Light
Yes
NonE
SOL OFF, DNA, Inhibit TCC
Yes
operation,
modulation
DNS, SOL OFF (hydraulic
Yes
default)
DNS, SOL OFF (hydraulic
Yes
default)
No Range Inhibit Use Current
Yes
Key-Cycle TID Level
No Neutral to Drive shifts for
refuse packer. TCM inhibits
No
retarder operation if a TPS
code is also active.
Ignore
Yes
selector inputs
No
None
No
None
Yes
Use default sump temp
Yes
Use default sump temp
Yes
Use default sump temp
Yes
DNS, Lock in current range
Yes
DNS, Lock in current range
Yes
DNS, Lock in current range
No
Neutral at Stop operation
Yes
None
Shift not in process, LIR
Shift in process, complete
shift then LIR. TCM forces
Yes
VMMS off. TCM inhibits
TCC
freezes shift adapts.
Inhibited Operation
Description
Inhibit
main
defective
strip
engagement.
TCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents