Download Print this page

Electrolux EDW 1600 Service Manual page 30

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

Service Code
Reason
Family
(Platform specific)
60
DIVA, DIVA2,
Heating problem
PB150(R100),
PB200, PB300
DIVA, DIVA2,
Heating – over temperature
PB150(R100),
PB200, PB300
DIVA, DIVA2,
Heater relay problems
PB150(R100),
PB200, PB300
PB100, PB101,
Heating system error 1
PB150(R110 or
later)
PB100, PB101,
Heater restorable
PB150(R110 or
later)
PB100, PB101,
Heater broken
PB150(R110 or
later)
PB100, PB101,
heating system error 2
PB150(R110 or
later)
PB100, PB101,
heating system error 3
PB150(R110 or
later)
PB100, PB101,
Water temperature is too high
PB150(R110 or
later)
PB100, PB101,
NTC on heat element value out of
PB150(R110 or
range
later)
PB100, PB101,
Heat timeout reached
PB150(R110 or
later)
PB101, PB150(R110
Heat exchange efficiency low
or later)
70
NTC problem
Technical Support – A.R.
Alarm Codes
Type
User
User
visible
indication
Please OBSERVE that i6x family has different meaning depending on PBs and PB firmware versions
warning
No
Nothing
abort
Yes
i61
warning
No
Nothing
warning
No
Nothing
warning
No
Nothing
warning
No
Nothing
warning
No
Nothing
warning
No
Nothing
abort
Yes
i69
warning
No
Nothing
warning
No
Nothing
Ack / warning
Yes / No
i6C
warning
No
Nothing
599 79 76 - 54 Rev 2
failure
Action in case of failure happens
code read
i60
Heating element will be switched off for the rest of the cycle
i61
Cycle will be terminated and electronic switched to reset on-condition
i62
Heating element will be switched off for the rest of the cycle
i63
Cycle continues running to the end
Causes in the order of probability:
broken heater
damaged harness/connectors
i64
Cycle continues running to the end
Heater is turned off for 1 minute, to be self -restored
Heater is OK
i65
Cycle continues running to the end without heating
i66
Cycle continues running to the end
Causes in the order of probability:
stuck neutral relay on power board
damaged harness/connectors
i67
Cycle continues running to the end
Causes in the order of probability:
stuck line relay on power board
damaged harness/connectors
i69
Water temperature detected > 78C
Cycle will be terminated and electronic switched to reset on -condition
Heater is OK
i6A
Cycle continues running
Heater will be deactivated for 5 minutes and recover if error condition
disappears
i6b (i6H)
Cycle continues running
Heater is switched off and restart in the next heating phase
Heater is OK
i6C
The efficiency of heat exchange between heater and water is low
Heater may need de -scaling
Heater is OK
i70
Heating element will be switched off for the rest of the cycle
User Indication
before March
2017
Nothing
i60
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
4
Chapter

Advertisement

loading

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010